Skip to main content
HAUNCH

CalculationsRC Column

RC Column

EN 1992-1-1

Checks a short RC column under axial load and biaxial bending to EN 1992-1-1.

Diagram

NEd=400kNM↻h=3000mm

Example inputs

Width b300 mm
Depth h300 mm
Clear height3000 mm
Axial load (NEd)400 kN
Moment My,Ed20 kNm
Moment Mz,Ed0 kNm
Concrete gradeC25/30
Main bar diameter20 mm
Bars per face3
Link diameter8 mm
Cover35 mm
National annexUK

Results

RC Column — 300×300mm

C25/30 · 3000mm height · EN 1992-1-1

Results

Slenderness PASS
util 0.9724.25EN 1992-1-1 §5.8.3
l0 effective length = 0.7 × h_clear (braced)2100mmEN 1992-1-1 §5.8.3.2
i radius of gyration = h / √1286.6mm
λ slenderness ratio = l0 / i24.25EN 1992-1-1 §5.8.3.1
n relative axial force = NEd / (Ac × fcd)0.314
λlim slenderness limit = 20 × A × B × C / √n25EN 1992-1-1 §5.8.3.1
Axial Capacity PASS
util 0.19400.00EN 1992-1-1 §6.1
fcd design concrete strength = 0.85 × fck / γC14.17N/mm²EN 1992-1-1 §3.1.6
fyd design steel strength = fyk / γS434.78N/mm²EN 1992-1-1 §3.2.7
As total steel area1884.96mm²
NRd axial resistance = Ac × fcd + As × fyd2068.13kNEN 1992-1-1 §6.1
Combined PASS
util 0.4520.00EN 1992-1-1 §5.8.9
d′ cover to bar centre = cover + link + φ/253mm
zs lever arm (steel to steel) = h − 2d′194mm
MRd moment resistance = As/2 × fyd × zs79.5kNmEN 1992-1-1 §5.8.9
NEd / NRd0.193
Meff / MRd0.252
Interaction ratio = NEd/NRd + Meff/MRd0.445EN 1992-1-1 §5.8.9
Min. Eccentricity PASS
util 0.0020.00EN 1992-1-1 §6.1(4)
e0 minimum eccentricity = max(h/30, 20mm)20mmEN 1992-1-1 §6.1(4)
Meff effective moment = max(My,Ed, NEd × e0)20kNm

Try it yourself

Run this calc with your own inputs

Open calculator →