Skip to main content
HAUNCH

CalculationsSteel UC Column

Steel UC Column

EN 1993-1-1

Checks a steel UC column for axial compression and combined axial-bending to EN 1993-1-1.

Diagram

NEd=500kNM↻h=3000mm203x203x46UC

Example inputs

Height3000 mm
Axial load (NEd)500 kN
Moment My,Ed10 kNm
Moment Mz,Ed0 kNm
Section203x203x46UC
Steel gradeS275
Eff. length factor (y)1
Eff. length factor (z)1
National annexUK

Results

Steel Column — 203x203x46UC

S275 · 3000mm height · EN 1993-1-1

Results

Squash PASS
util 0.31500.00EN 1993-1-1 §6.2.4
fy yield strength = from grade and tf275N/mm²EN 1993-1-1 Table 3.1
A cross-sectional area58.7cm²
Npl,Rd plastic axial resistance = A × fy / γM01614.25kNEN 1993-1-1 §6.2.4
Buckling Y PASS
util 0.33500.00EN 1993-1-1 §6.3.1
Lcr,y buckling length (y) = ky × h3000mm
iy radius of gyration (y)8.82cm
λ̄y non-dimensional slenderness (y) = (Lcr/i) / λ10.392EN 1993-1-1 §6.3.1.3
αy imperfection factor (y)0.34EN 1993-1-1 Table 6.1
φy = 0.5[1 + α(λ̄−0.2) + λ̄²]0.609
χy reduction factor (y) = 1/(φ+√(φ²−λ̄²))0.929EN 1993-1-1 §6.3.1.2
Nb,Rd,y buckling resistance (y) = χy × A × fy / γM11499.64kNEN 1993-1-1 §6.3.1.1
Buckling Z PASS
util 0.42500.00EN 1993-1-1 §6.3.1
Lcr,z buckling length (z) = kz × h3000mm
iz radius of gyration (z)5.13cm
λ̄z non-dimensional slenderness (z) = (Lcr/i) / λ10.674EN 1993-1-1 §6.3.1.3
αz imperfection factor (z)0.49EN 1993-1-1 Table 6.1
φz = 0.5[1 + α(λ̄−0.2) + λ̄²]0.843
χz reduction factor (z) = 1/(φ+√(φ²−λ̄²))0.741EN 1993-1-1 §6.3.1.2
Nb,Rd,z buckling resistance (z) = χz × A × fy / γM11196.16kNEN 1993-1-1 §6.3.1.1
Combined PASS
util 0.49500.00EN 1993-1-1 §6.3.3
Nb,Rd,min governing buckling resistance1196.16kN
Mc,Rd moment resistance = Wpl,y × fy / γM0136.68kNmEN 1993-1-1 §6.2.5
NEd / Nb,Rd ratio = NEd / Nb,Rd,min0.418
My,Ed / Mc,Rd ratio = My,Ed / Mc,Rd0.073
Interaction ratio = NEd/Nb,Rd + My/Mc,Rd0.491EN 1993-1-1 §6.3.3

Try it yourself

Run this calc with your own inputs

Open calculator →