Skip to main content
HAUNCH

CalculationsRHS/SHS Column

RHS/SHS Column

EN 1993-1-1

EN 1993-1-1 RHS/SHS column — compression and buckling

Example inputs

Section100x100x5SHS
Steel gradeS275
NEd (kN)200 kN
Effective Length Y (mm)3000 mm
Effective Length Z (mm)3000 mm
Cold-formedfalse
National annexUK

Results

RHS/SHS Column — 100x100x5SHS

S275 · NEd=200kN · EN 1993-1-1

Results

CROSS SECTION PASS
util 0.331.00EN 1993-1-1 §5.5 Table 5.2
ε = √(235/fy) = √(235/fy)0.924EN 1993-1-1 §5.5
c_web / t (web) = (h−3t)/t17
c_flange / t (flange) = (b−3t)/t17
Web class1
Flange class1
Section class1
COMPRESSION RESISTANCE PASS
util 0.38200.00EN 1993-1-1 §6.2.4
fy yield strength275N/mm²EN 1993-1-1 Table 3.1
A cross-section area1900mm²
NEd design axial force200kN
NRd compression resistance = A × fy / γM0522.5kNEN 1993-1-1 §6.2.4
BUCKLING Y PASS
util 0.57200.00EN 1993-1-1 §6.3.1
Lcr,y effective length y-y3000mm
Iy second moment of area y-y286.6cm⁴
Ncr,y elastic critical force y-y = π²EIy / Lcr,y²660.01kNEN 1993-1-1 §6.3.1
λ̄y slenderness y-y = √(A·fy / Ncr,y)0.89
α imperfection factor0.34EN 1993-1-1 Table 6.2, curve b
φy = 0.5[1 + α(λ̄y − 0.2) + λ̄y²]1.013
χy reduction factor = 1/(φy+√(φy²−λ̄y²))0.668EN 1993-1-1 §6.3.1.2
Nb,Rd,y buckling resistance y-y = χy × A × fy / γM1349.03kN
BUCKLING Z PASS
util 0.57200.00EN 1993-1-1 §6.3.1
Lcr,z effective length z-z3000mm
Iz second moment of area z-z286.6cm⁴
Ncr,z elastic critical force z-z = π²EIz / Lcr,z²660.01kNEN 1993-1-1 §6.3.1
λ̄z slenderness z-z = √(A·fy / Ncr,z)0.89
α imperfection factor0.34EN 1993-1-1 Table 6.2, curve b
φz = 0.5[1 + α(λ̄z − 0.2) + λ̄z²]1.013
χz reduction factor = 1/(φz+√(φz²−λ̄z²))0.668EN 1993-1-1 §6.3.1.2
Nb,Rd,z buckling resistance z-z = χz × A × fy / γM1349.03kN

Try it yourself

Run this calc with your own inputs

Open calculator →